Electrodeionization (EDI) Repair

December 19, 2025

tin tức mới nhất của công ty về Electrodeionization (EDI)  Repair

EDI Module Maintenance: Resin Replacement

1. Safety & Prep

  • Wear PPE: gloves, goggles

  • Shut off power/water, drain module

  • Have new resin, tools, containers ready

2. Remove Old Resin

  • Disconnect pipes/wires (label first)

  • Unbolt end plates carefully

  • Pour out old resin into waste container

  • Rinse chambers with DI water

3. Add New Resin

  • Mix new resin with DI water to make slurry

  • Use funnel to fill each chamber completely

  • Tap gently to remove air pockets

  • Clean seal surfaces

4. Reassemble

  • Install new O-rings (lightly lubricate)

  • Rebolt end plates evenly (follow torque specs)

  • Reconnect all pipes and wires

5. Restart & Check

  • Flush with water to remove air

  • Power on gradually

  • Monitor for leaks

  • Check water quality reaches >15 MΩ·cm

Key Tips:

  • Work cleanly, avoid contamination

  • Follow manufacturer torque values

  • Document resin lot number and date

  • Investigate cause of resin failure

Time: 4-6 hours
Frequency: Every 2-5 years, or when quality drops